TRK-2P, Kerato-refractometer, tono-pachymeter



Short description

The TRK-2P is a unique 4 in 1 instrument. With a single touch of a fingertip on the rotatable control touch panel, not only Refract-Keratometry is measured but also Tono-Pachymetry. Read more>

Key Features

  • 4 in 1: refraction, keratometry, tonometry and pachymetry
  • Fully automated with rotatable control touch panel
  • Soft air-puff
  • Adjusted IOP
  • Ergonomic design
  • Small footprint

Related Products



Specifications

Measuring range refraction Spherical refractive power: -30D to +25D (0.12D/0.25D steps)
Cylindrical refractive power: 0D to +/- 12D (0.12D/0.25D steps)
Direction of astigmatic axis: 0° to 180° (1°/5° steps)
Minimum measurable pupil diameter Ø2.0mm
PD measurement range 20mm to 85mm (0.5mm step)
Target fixation Auto fog system
Measuring range keratometry Cornea curvature radius: 5.00mm to 13.00mm (0.01mm step)
Corneal refractive power: 67.50D to 25.96D (0.12D/0.25D steps)
(where corneal refractive power index = 1.3375D)
Corneal astigmatic power: 0D to +/-12D (0.12D/0.25D steps)
Direction of corneal astigmatic axis: 0° to 180° (1°/5° steps)
Measuring range tonometry 1 to 60 mmHg (1mmHg step)
Measuring range pachymetry 0.400mm to 0.750mm (0.001mm step)
Chinrest travel distance Up/down 67mm
Dimensions 293-396mm(W) x 505-601mm(D) x 470-682mm(H)
Weight 22 Kgs
Power supply 100-240V AC, 50-60Hz, 100VA


Description

The TRK-2P combines a refractometer, a keratometer, a non-contact tonometer and a pachymeter in one compact instrument. The TRK-2P features a fully auto alignment system with auto measurement function. The compact size and 8,5” rotating color touch screen control panel offers total flexibility for the operator and also for instrument location. With just one touch of the fingertip on the control panel, the TRK-2P will measure both eyes accurately due to Topcon’s exclusive Rotary Prism Technology.

Cataract mode
The TRK-2P has a built-in function that allows measurement of patients who have a cataract or an opacity. This function works automatically or manually.

Softer air-puff
Improved nozzle design and software control the optimal amount of air required for every IOP measurement. A softer air puff improves patient comfort and results in an improved measurement experience.

Adjusted IOP
The built-in pachymeter function can be used to adjust the measured IOP value, depending on the cornea: if it is thicker or thinner than average. The integrated formula for IOP adjustment can be customized by the eye care practitioner.

 